The tool supports students in reading and interpreting basic electrical diagrams (single-line and multi-line), recognising cable colour codes, and applying electrical safety rules and relevant CEI/IEC standards in electrical installations.
Contents:
Single-line and multi-line electrical diagrams: structure and meaning Reading and interpretation of basic electrical schematics
Cable colour codes according to standards
Electrical safety principles and use of PPE (Personal Protective Equipment) Reference CEI / IEC standards for electrical installations
Exemplary diagrams and regulatory references
https://qelectrotech.org/forum/misc.php?action=pun_attachment&item=2124&download=1
| IEC SYMBOL | IEC DESCRIPTION | COMMENTS |
![]() |
Connection, General Symbol Alternative: Conductor; Cable; Line; Transmission Path;Telecommunication Line. |
Levels are in place indicating the type of conductor: Power_Cable, |
![]() |
Group of Connections (Number of Connections Indicated) (form 1) |
3 Phases / 3 Connections |
![]() |
Group of Connections (Number of Connections Indicated) (form 2) |
3 Phases / 3 Connections |
![]() |
3-Phase Circuit | Additional Information may be indicated |
![]() |
Flexible Connection | Used as trailing cable symbology |
![]() |
Screened Conductor | |
![]() |
Twisted Connection | Two connections shown |
![]() |
Conductors in a Cable | Five conductors, two of which marked by arrowheads are in one cable. |
![]() |
Coaxial Pair | |
![]() |
Coaxial Pair Connected to Terminals | |
![]() |
Coaxial Pair with screen | |
![]() |
Terminal | |
![]() |
Terminal Strip | |
![]() |
T-Connection (form 1) | |
![]() |
T-Connection (form 2) | Shown with junction symbol. |
![]() |
Double junction of conductors (form 1) | |
![]() |
Double junction of conductors (form 2) | |
![]() |
Brancing | ![]() |
![]() |
Neutral Point | |
![]() |
Neutral point of a generator (single-line representation) | |
![]() |
Neutral point of a generator (multi-line representation) | |
![]() |
Contact, female(of a socket or plug) Socket |
|
![]() |
Contact, male (of a socket or plug) Plug |
|
![]() |
Plug and socket | |
![]() |
Plug and socket, multipole (multi-line representation) |
|
![]() |
Plug and socket, multipole (multi-line representation) |
|
![]() |
Connecting link, closed Test terminal, twin stud type (form 1) |
|
![]() |
Connecting link, closed (form2) |
|
![]() |
Connecting link, open | |
![]() |
Plug and socket-type connector, male-male U-link |
|
![]() |
Plug and socket-type connector, male-female U-link |
|
![]() |
Plug and socket-type connector, male-male with socket access | |
![]() |
Cable sealing end (multi-core cable) | |
![]() |
Cable sealing end (one-core cable) | |
![]() |
Straight-through joint box (multi-line representation) |
|
![]() |
Straight-through joint box (single-line representation) |
|
![]() |
Junction box (multi-line representation) | |
![]() |
Junction box (single-line representation) | |
![]() |
Pressure-tight bulkhead cable gland | |
![]() |
Triode thyristor, type unspecified | |
![]() |
Object Equipment: Device, Funtional unit, Component, Function (form 1) |
|
![]() |
Object Equipment: Device, Funtional unit, Component, Function (form 2) |
|
![]() |
Object Equipment: Device, Funtional unit, Component, Function (form 3) |
|
![]() |
Envelope (form 2) |
|
![]() |
Boundary | |
![]() |
Shield | |
![]() |
Protection against unintentional direct contact, general symbol |
|
![]() |
Alternating Current (form 1) | Replacing S00067 |
![]() |
Alternating current (indication of frequency) | Shown for alternating current of 50 Hz. |
![]() |
Alternating Current (Indicationn of frequency range: low) Different frequency ranges. Relatively low frequencies (power frequencies or sub-audio frequencies) |
|
![]() |
Alternating Current (indication of frequency range: medium) Different frequency ranges. Medium frequencies (audio) |
|
![]() |
Alternating Current (indication of frequency range: high) Different frequency ranges.Relatively high frequencies (super audio, carrier) |
|
![]() |
Rectifier current with alternating component | |
| + | Positive polarity | |
| - | Negative polarity | |
| N | Neutral | |
| M | Mid-wire | |
![]() |
Adjustibility, general symbol | |
![]() |
Adjustibility, non-linear | |
![]() |
Variability,general symbol | |
![]() |
Variability,non-linear | |
![]() |
Adjustability, pre-set | |
![]() |
Pre-set adjustibility | |
![]() |
Action in steps | 5 steps shown. |
![]() |
Adjustibility step by step | |
![]() |
Continious variability | |
![]() |
Continious variability pre-set Pre-set adjustment, continuously variable |
|
![]() |
Automatic control | |
![]() |
Amplifier with automatic gain control | |
![]() |
Rectilinear motion (unidirectional) Force; Unidirectional, in the direction of the arrowhead |
|
![]() |
Rectilinear motion (bidirectional) Force |
|
![]() |
Oscillating motion | |
![]() |
Thermal effect | |
![]() |
Electromagnetic effect | |
![]() |
Magnetostrictive effect | |
![]() |
Radiation, electromagnetic, non-ionizing Light |
|
![]() |
Step function, positive going | |
![]() |
Step function, negative going | |
![]() |
Saw-tooth wave | |
![]() |
Facsimile | |
![]() |
Link Mechanical link, pneumatic link, hydraulic link, optical link, functional link, radio link |
|
![]() |
Mechanical link (force or motion) Link, mechanical ; Mechanical link with indication of direction of force or motion |
|
![]() |
Mechanical link (rotation) Link, mechanical; Mechanical link with indication of direction of rotation. |
|
![]() |
Delayed action Action, delayed (form 1) |
|
![]() |
Delayed action Action, delayed (form 2) |
|
![]() |
Automatic return | |
![]() |
Detent Non-automatic return; Return, non-automatic; Device for maintaining a given position |
|
![]() |
Detent, disengaged | |
![]() |
Detent, engaged | |
![]() |
Mechanical interlock Interlock, mechanical; Mechanical interlock between two devices |
|
![]() |
Brake | |
![]() |
Brake, applied Electric motor with brake applied. |
|
![]() |
Brake, released Electric motor with brake released |
|
![]() |
Gearing | |
![]() |
Actuator, manual, general symbol | |
![]() |
Actuator, manual (Protected) Manual actuator protected against unintentional operation |
|
![]() |
Actuator (operated by pulling) | |
![]() |
Actuator (operated by pulling) | |
![]() |
Actuator (opetated by pushing) | |
![]() |
Actuator (operated by proximity effect) | |
![]() |
Actuator (operated by touching) | |
![]() |
Actuator, emergency Emergency actuator, type "mushroom-head" |
|
![]() |
Actuator (operated by handwheel) | |
![]() |
Actuator (operated by pedal) | |
![]() |
Actuator (operated by lever) | |
![]() |
Actuator (operated by removable handle) | |
![]() |
Actuator (operated by key) | |
![]() |
Actuator (operated by crank) | |
![]() |
Actuator (operated by roller) | |
![]() |
Actuator (operated by cam) | |
![]() |
Actuator (operated by cam/cam profile) | |
![]() |
Actruator (operated by cam/profile plate) | |
![]() |
Actuator (operated by cam and roller) | |
![]() |
Actuator (operated by stored mechanical energy) |
|
![]() |
Actuator (actuated by pneumatic or hydraulic power/single action) Single acting actuator |
|
![]() |
Actuator (actuated by pneumatic or hydraulic power/double action) Double acting actuator |
|
![]() |
Actuator (actuated by electromagnetic effect) | |
![]() |
Actuator (operated by electric motor) | |
![]() |
Actuator (operated by electric clock) | |
![]() |
Actuator (semiconductor) Semiconductor actuator |
|
![]() |
Actuator (actuated by liquid level) | |
![]() |
Actuator (actuated by a counter) | |
![]() |
Actuator (actuated by fluid flow) | |
![]() |
Actuator (actuaded by gas flow) | |
![]() |
Actuator (actuated by relative humidity) | |
![]() |
Earth, general symbol Earthing, general symbol; Ground (US), general symbol; Grounding (US), general symbol |
|
![]() |
Functional equipotential bonding Functional bonding conductor; Functional bonding terminal |
|
![]() |
Functional equipotential bonding Functional bonding conductor; Functional bonding terminal Simplified form |
|
![]() |
Protective equipotential bonding Protective bonding conductor; Protective bonding terminal |
|
![]() |
Fault Indication of assumed fault location |
|
![]() |
Flashover Break-through |
|
![]() |
Permanent Magnet Magnet, permanent |
|
![]() |
Movable contact Sliding contact |
|
![]() |
Test point indicator | |
![]() |
Converter, general symbol Power converter; Signal converter; Measuring transducer; Repeater |
|
![]() |
Contactor function | |
![]() |
Circuit breaker function | |
![]() |
Disconnector (isolator) function | |
![]() |
Switch-disconnector function Isolating-switch function |
|
![]() |
Make contact, general symbol, switch, general symbol |
|
![]() |
Break contact | |
![]() |
Change-over break before make contact | |
![]() |
Change-over contact with off-position | |
![]() |
Change-over make before break contact, both ways (form 1) |
|
![]() |
Change-over make before break contact, both ways (form 1) |
|
![]() |
Make contact delayed closing | |
![]() |
Make contact delayed opening | |
![]() |
Make contact, delayed opening | |
![]() |
Break contact, delayed closing | |
![]() |
Make contact, delayed | |
![]() |
Contact assembly | |
![]() |
Switch, manually operated, general symbol | |
![]() |
Switch, manually operated, push-button, automatic return |
|
![]() |
Switch, manually operated, pulling, automatic return | |
![]() |
Switch, maually operated, turning, stay-put | |
![]() |
Switch, maually operated with positive operation, push-button, automatic return Alarm switch |
|
![]() |
Switch, emergency stop | |
![]() |
Position switch, make contact | |
![]() |
Position switch, break contact | |
![]() |
Position switch assembly | |
![]() |
Position switch, break contact, positive operation Limit switch |
|
![]() |
Temperature sensitive switch, make contact | |
![]() |
Temperature sensitive switch, break contact | |
![]() |
Thermal switch, self-operating, break contat Bimetal break contact |
|
![]() |
Gas discharge tube with thermal element Starter for fluorescent lamp |
|
![]() |
Contactor; Main make contact of a contactor | |
![]() |
Contactor with automatic tripping | |
![]() |
Contactor, main break contact of a contactor | |
![]() |
Circuit Breaker | |
![]() |
Disconnector, Isolator | |
![]() |
Two-way disconnector, Two-way isolator | |
![]() |
Switch-dosconnector, On-load isolating switch | |
![]() |
Switch-disconnector, automatic release, On-load isolating switch, automatic release |
|
![]() |
Disconnector, Isolator | |
![]() |
Trip-free mechanism | |
![]() |
Trip-free mechanism, application | |
![]() |
Mechanical switching device, three-pole | |
![]() |
Switch with positive opening | |
![]() |
Motor starter, general symbol | |
![]() |
Starter operating in steps | |
![]() |
Starter-regulator | |
![]() |
Direct-on-line starter, reversing | |
![]() |
Star-delta starter | |
![]() |
Starter with auto-transformer | |
![]() |
Starter-regulator with thyristor | |
![]() |
Operating device, general symbol; Relay coil, general symbol Operating coil of a selector (form 1) |
|
![]() |
Relay coil of a slow-releasing relay | |
![]() |
Relay coil of a slow-operating relay | |
![]() |
Relay coil of a remanent relay (form 1) |
|
![]() |
Relay coil of a remanent relay (form 2) |
|
![]() |
Operating device of a thermal relay | |
![]() |
Measuring relay, Device related to a measuring relay |
|
![]() |
Voltage failure to frame; Frame potential in case of fault |
|
![]() |
Earth fault current | |
![]() |
Fuse, general symbol | |
![]() |
Fuse ; strike fuse | With mechanical linkage. |
![]() |
Fuse with alarm contact | |
![]() |
Fuse with separate alarm | |
![]() |
Three-pole switch with striker fuses | |
![]() |
Fuse-switch | |
![]() |
Fuse-disconnector; Fuse isolator | |
![]() |
Fuse switch-disconnector; On-load isolating fuse switch |
|
![]() |
Spark gap | |
![]() |
Spark gap, double | |
![]() |
Surge diverter; Lightning arrester | |
![]() |
Protective gas discharge tube | |
![]() |
Protective gas discharge tube, symmetic | |
![]() |
Generating station, planned | |
![]() |
Generating station, in service or unspecified | |
![]() |
Combined electric and heat generated station, planned |
|
![]() |
Combined electric and heat generating station, in service or unspecified |
|
![]() |
Substation, planned | |
![]() |
Substation, in service or unspecified | |
![]() |
Hydroelectric generating station, planned | |
![]() |
Hydroelectric generating station, in service or unspecified |
|
![]() |
Thermoelectric generating station, planned coal thermoelectric generating station; lignite thermoelectric generating station; oil thermoelectric generating station; gas thermoelectric generating station |
|
![]() |
Thermoelectric generating station, in service or unspecified thermoelectric generating station coal; thermoelectric generating station lignite; thermoelectric generating station oil; thermoelectric generating station gas |
|
![]() |
Nuclear energy generating station, planned | |
![]() |
Nuclear energy generating station, in service or unspecified |
|
![]() |
Geothermic generating station, planned | |
![]() |
Geothermic generating station, in service or unspecified | |
![]() |
Solar generating station, planned | |
![]() |
Solar generating station, in service or unspecified | |
![]() |
Wind generator station, planned | |
![]() |
Wind generator station, in service or unspecified | |
![]() |
Underground Line | |
![]() |
Submarine Line | |
![]() |
Overhead Line | |
![]() |
Line with a duct; Line within a pipe | Additional info. may be shown above the line representing the duct route. |
![]() |
Line within a six-way-duct | Additional info. may be shown above the line representing the duct route. |
![]() |
Manhole for underground chamber | Additional info. may be shown above the line representing the duct route. |
![]() |
Head end with local antenna | |
![]() |
Directional Coupler, General Symbol | |
![]() |
Neutral conductor | The symbol could be replaced by letter symbols in IEC 60445 |
![]() |
Protective conductor | The symbol could be replaced by letter symbols in IEC 60445 |
![]() |
Combined protective & neutral conductor | The symbol could be replaced by letter symbols in IEC 60445 |
![]() |
3-phase wiring with neutral conductor & protective conductor | The symbol could be replaced by letter symbols in IEC 60445 |
![]() |
Wiring going upwards | If the arrow is pointing to the top border (edge) of the drawing sheet, the wiring goes upward. |
![]() |
Wiring going downwards | If the arrow is pointing towards the bottom border (edge) of the drawing sheet, the wiring goes downward |
![]() |
Wiring passing through vertically | |
![]() |
Box, General symbol | |
![]() |
Connection box; Junction box | |
![]() |
Consumers terminal, Service entrance equipment |
|
![]() |
Distribution centre | |
![]() |
Socket outlet (power) general symbol | |
![]() |
Multiple socket outlet (power) | Form 1 |
![]() |
Multiple socket outlet (power) | Form 2 |
![]() |
Socket outlet (power) with protective contact | |
![]() |
Socket outlet (power) with sliding shutter | |
![]() |
Socket outlet (power) with single-pole switch | |
![]() |
Socket outlet (power) with interlocked switch | |
![]() |
Socket outlet (power) with isolating transformer | Designations in accordance with relevant IEC or ISO standards to show different type connections & outlet symbols: |
![]() |
Switch, general symbol | |
![]() |
Switch with pilot light | |
![]() |
Period limiting switch, single-pole | |
![]() |
2 pole switch | |
![]() |
Multiposition single pole switch | |
![]() |
2 way single pole switch | |
![]() |
Intermediate switch |
Equivalent circui diagram
|
![]() |
Dimmer | |
![]() |
Pull-cord single pole switch | |
![]() |
Push-button | |
![]() |
Push-button with indicator lamp | |
![]() |
Push-button protected against unintentional operation | Protection can be by means of a breakglass cover |
![]() |
Time switch | |
![]() |
Key-operated switch Watchman's system device |
|
![]() |
Lighting outlet position | |
![]() |
Lighting outlet on wall | |
![]() |
Luminaire, general symbol; Flourescent lamp, general symbol |
|
![]() |
Luminaire with many flourescent tubes. | |
![]() |
Luminaire with many flourescent tubes. | |
![]() |
Projector, general symbol | |
![]() |
Spot light | |
![]() |
Flood light | |
![]() |
Emergency lighting luminaire on special circuit | |
![]() |
Self-contained emergency lighting luminaire | |
![]() |
Water heater | |
![]() |
Time clock, time recorder | |
![]() |
Resistor, general symbol | |
![]() |
Resistor, adjustable | |
![]() |
Resistor, voltage dependant Varistor |
|
![]() |
Resistor with movable contact | |
![]() |
Resistor with movable contact and off position | |
![]() |
Potentiameter with movable contact | |
![]() |
Potentiometer with movable contact and pre-set adjustment |
|
![]() |
Resistor with fixed tappings | |
![]() |
Resistor with separate current and voltage | |
![]() |
Carbon-pile resistor | |
![]() |
Heating element | |
![]() |
Capacitor, general symbol | |
![]() |
Capacitor, polirized Electrolytic capacitor |
|
![]() |
Capacitor, adjustable | |
![]() |
Capacitor with pre-set adjustment | |
![]() |
Capacitor, differential | |
![]() |
Capacitor, split and adjustable | |
![]() |
Capasitor, temperature dependent and polirised | |
![]() |
Capacitor, voltage dependent and polirised Semiconductor capacitor |
|
![]() |
Coil, general symbol; Winding, general symbol Inductor; Choke |
|
![]() |
Inductor with magnetic core | |
![]() |
Inductor with gap in magnetic core | |
![]() |
Inductor, continuously variable | |
![]() |
Inductor with fixed tappings | |
![]() |
Inductor with maveable contact, variable in steps | |
![]() |
Variometer | |
![]() |
Semiconductor diode, general symbol | |
![]() |
Light emitting diode (LED), general symbol | |
![]() |
Temperature sensing diode | |
![]() |
Variable capacitance diode Varactor |
|
![]() |
Tunnel diode Esaki diode |
|
![]() |
Breakdown diode, unidirectional Zener diode; Voltage regulator diode |
|
![]() |
Breakdown diode, bidirectional | |
![]() |
Backward diode (unitunnel diode) | |
![]() |
Bidirectional diode | |
![]() |
Reverse blocking diode thyristor | |
![]() |
Reverse conducting diode thyristor | |
![]() |
Bidirectional diode thyristor; Diac | |
![]() |
Reverse blocking triode thyristor, N-gate (anode-side controlled) |
|
![]() |
Reverse blocking triode thyristor, P-gate (cathode-side controlled) |
|
![]() |
Turn-off thyristor, gate not specified | |
![]() |
Turn-off triode thyristor, N-gate (anode-side) | |
![]() |
Turn-off triode thyristor, P-gate (cathode-side controlled) |
|
![]() |
Reverse blocking thyristor, tetrode type | |
![]() |
Bidirectional triode thyristor; Triac | |
![]() |
Reverse conducting triode thyristor, gate not specified |
|
![]() |
Reverse conducting triode thyristor, N-gate (anode-side controlled) |
|
![]() |
Reverse conducting triode thyristor, P-gate (cathode-side controlled) |
|
![]() |
PNP transistor | |
![]() |
NPN transistor with collector connected to the envelope |
|
![]() |
NPN avalanche transistor | |
![]() |
Unijunction transistor with P-type base | |
![]() |
Unijunction transistor with N-type base | |
![]() |
NPN transistor with transverse biased base | |
![]() |
PNIP transistor with connection to the intrinsic region |
|
![]() |
PNIN transistor with connection to the intrinsic region |
|
![]() |
Junction field effect transistor with N-type channel | The gate and source connections shall be drawn in line. |
![]() |
Junction field effect transistor with P-type channel | The gate and source connections shall be drawn in line. |
![]() |
Insulated gate field effect transistor IGFET enhancement type, single gate, P-type channel without substrate connection | |
![]() |
Insulated gate field effect transistor IGFET enhancement type, single gate, N-type channel without substrate connection | |
![]() |
Insulated gate field effect transistor IGFET enhancement type, single gate, P-type channel with substrate connection brought out | |
![]() |
Insulated gate field effect transistor IGFET enhancement type, single gate, N-type channel with substrate internally connected to source | |
![]() |
Insulated gate field effect transistor IGFET, depletion type, single gate, N-type channel without substrate connection | |
![]() |
Insulated gate field effect transistor IGFET, depletion type, single gate, P-type channel without substrate connection | |
![]() |
Insulated gate field effect transistor IGFET, depletion type, two gates, P-type channel with substrate connection brought out | In the case of multiple gates, the primary gate and the source connection shall be drawn in line. |
![]() |
Insulated-gate bipolar transistor (IGBT) enhancement type, P channel | |
![]() |
Insulated-gate bipolar transistor (IGBT) enhancement type, N channel | |
![]() |
Insulated-gate bipolar transistor (IGBT) depletion type, P channel | |
![]() |
Insulated-gate bipolar transistor (IGBT) depletion type, N channel | |
![]() |
Light dependent resistor (LDR); Photo resistor | |
![]() |
Photodiode | |
![]() |
Photovoltaic cell | |
![]() |
Phototransistor | |
![]() |
Hall generator with four connections | |
![]() |
Magnetoresistor | |
![]() |
Three-phase winding, delta | |
![]() |
Three-phase winding, open delta | |
![]() |
Three-phase winding, star | |
![]() |
Three-phase winding, star, with neutral brought out |
|
![]() |
Brush (on slip-ring or commutator) | |
![]() |
Machine, general symbol Rotary converter; Generator; Synchronous generator; Motor; Synchronous motor |
|
![]() |
Linear motor, general symbol | |
![]() |
Stepping motor, general symbol | |
![]() |
Series motor, DC | |
![]() |
Shunt motor, DC | |
![]() |
Generator, DC, compound excited (short shunt) | |
![]() |
Rotary converter, DC/DC with common permanent magnet field |
|
![]() |
Rotary converter, DC/DC with common exitation winding |
|
![]() |
Series motor, single-phase | |
![]() |
Repulsion motor, single-phase | |
![]() |
Series motor, three-phase | |
![]() |
Synchronous generator, three-phase with permanent magnet | |
![]() |
Synchronous motor, single-phase | |
![]() |
Synchronous generator, three-phase, star connected, neutral brought out | |
![]() |
Synchronous generator, three-phase, both ends of each phase winding brought out |
|
![]() |
Synchronous rotary converter, three-phase, shunt-excited |
|
![]() |
Induction motor, three-phase, squirrel cage | |
![]() |
Induction motor, single-phase, squirrel-cage | |
![]() |
Induction motor, three-phase, with wound rotor | |
![]() |
Induction motor, three-phase, star-connected | |
![]() |
Linear induction motor, three-phase | |
![]() |
Transformer with two windings, general symbol (form 1) |
|
![]() |
Transformer with two windings, general symbol (form 2) |
|
![]() |
Transformer with two windings (and instantaneous voltage polarity indicators) (form 2) |
|
![]() |
Transformer with three windings, general symbol (form 1) |
|
![]() |
Transformer with three windings, general symbol (form 2) |
|
![]() |
Auto-transformer, general symbol (form 1) |
|
![]() |
Auto-transformer, general symbol (form 2) |
|
![]() |
Reactor, general symbol Choke (form 1) |
|
![]() |
Reactor, general symbol Choke (form 2) |
|
![]() |
Current transformer, general symbol (form 1) |
|
![]() |
Current transformer, general symbol (form 2) |
|
![]() |
Transformer with two windings and screen (form 1) |
|
![]() |
Transformer with two windings and screen (form 2) |
|
![]() |
Transformer with centre tap on one winding (form 1) |
|
![]() |
Transformer with centre tap on one winding (form 2) |
|
![]() |
Transformer with variable coupling (form 1) |
|
![]() |
Transformer with variable coupling (form 2) |
|
![]() |
Three-phase transformer, connection star-delta (form 1) |
|
![]() |
Three-phase transformer, connection star-delta (form 2) |
|
![]() |
Three-phase transformer with four taps, connection: star-star (form 1) |
|
![]() |
Three-phase transformer with four taps, connection: star-star (form 2) |
|
![]() |
Three-phase bank of single-phase transformers, connection star-delta (form 1) |
|
![]() |
Three-phase bank of single-phase transformers, connection star-delta (form 2) |
|
![]() |
Three-phase transformer with tap changer (form 1) |
|
![]() |
Three-phase transformer with tap changer (form 2) |
|
![]() |
Three-phase transformer, connection star-zigzag with the neutral brought out (form 1) |
|
![]() |
Three-phase transformer, connection star-zigzag with the neutral brought out (form 2) |
|
![]() |
Three-phase transformer, connection star-star-delta (form 1) |
|
![]() |
Three-phase transformer, connection star-star-delta (form 2) |
|
![]() |
Auto-transformer, single-phase (form 1) |
|
![]() |
Auto-transformer, single-phase (form 2) |
|
![]() |
Auto-transformer, three-phase, connection star (form 1) |
|
![]() |
Auto-transformer, three-phase, connection star (form 2) |
|
![]() |
Auto-transformer, single-phase with voltage regulation (form 1) |
|
![]() |
Auto-transformer, single-phase with voltage regulation (form 2) |
|
![]() |
Three-phase induction regulator (form 1) |
|
![]() |
Three-phase induction regulator (form 2) |
|
![]() |
Voltage transformer Measuring transformer (form 1) |
|
![]() |
Voltage transformer Measuring transformer (form 2) |
|
![]() |
Current transformer with two cores with one secondary winding on each core (form 1) |
|
![]() |
Current transformer with two cores with one secondary winding on each core (form 2) |
|
![]() |
Current transformer with two secondary windings on one core (form 1) |
|
![]() |
Current transformer with two secondary windings on one core (form 2) |
|
![]() |
Current transformer with one secondary winding with one tap (form 1) |
|
![]() |
Current transformer with one secondary winding with one tap (form 2) |
|
![]() |
Current transformer with five passages of a conductor acting as a primary winding (form 1) |
|
![]() |
Current transformer with five passages of a conductor acting as a primary winding (form 2) |
|
![]() |
Pulse or current transformer with three threaded primary conductors (form 1) |
|
![]() |
Pulse or current transformer with three threaded primary conductors (form 2) |
|
![]() |
Pulse or current transformer with two secondary windings on the same core (form 1) |
|
![]() |
Pulse or current transformer with two secondary windings on the same core (form 2) |
|
![]() |
DC/DC converter Chopper |
|
![]() |
Rectifier | |
![]() |
Rectifier in full wave (bridge) connection | |
![]() |
Inverter | |
![]() |
Rectifier/inverter | |
![]() |
Primary cell | |
![]() |
Static generator, general symbol | |
![]() |
Heat source, general symbol | |
![]() |
Radio-isotope heat source | |
![]() |
Combustion heat source | |
![]() |
Thermoelectric generator, with combustion heat source |
|
![]() |
Thermoelectric generator with non ionizing radiation heat source |
|
![]() |
Thermoelectric generator with radio-isotope heat source |
|
![]() |
Thermionic diode generator with non-ionizing heat source |
|
![]() |
Thermionic diode generator with radio-isotope heat source |
|
![]() |
Photovoltaic generator | |
![]() |
Closed-loop controller | |
![]() |
Indicating instrument, genral symbol | |
![]() |
Recording instrument, genral symbol | |
![]() |
Intergrading instrument, general symbol Energy meter |
|
![]() |
Voltmeter | |
![]() |
Recording wattmeter | |
![]() |
Watt-hour meter | |
![]() |
Watt-hour, measuring energy transmitted in one direction only |
|
![]() |
Watt-hour meter, counting the energy flow from the busbar |
|
![]() |
Watt-hour meter, counting the energy flow towards the busbars |
|
![]() |
Watt-hour meter, counting in both energy flow directions |
|
![]() |
Multi-rate watt-hour meter | |
![]() |
Excess watt-hour meter | |
![]() |
Watt-hour meter with transmitter | |
![]() |
Slave watt-hour mater (repeater) | |
![]() |
Slave watt-hour meter (repeater) with printing device |
|
![]() |
Thrmocouple | |
![]() |
Thermocouple with non-insulated heating element |
|
![]() |
Thermocouple with insulated heating element | |
![]() |
Clock, general symbol secondary clock |
|
![]() |
Clock with contact | |
![]() |
Lamp, general symbol lamp, general symbol; signal lamp, general symbol |
|
![]() |
Signal lamp, flashing type | |
![]() |
Indicator, electromechanical; annunciator element | |
![]() |
Electromechanical position indicator | |
![]() |
Siren | |
![]() |
Buzzer | |
![]() |
Signalling lamp energized by a built-in transformer |
|
![]() |
Selector wiper, non-bridging | The small circle representing the hinge point may be open or filled in. |
![]() |
Selector wiper, bridging | The small circle representing the hinge point may be open or filled in. |
![]() |
Arc or bank of single-motion selector | |
![]() |
Arc or bank of two-motion selector | |
![]() |
Selector arc with one special position | An example of a special position is the home position. |
![]() |
Selector bank or level | The groups of outlets or contacts may be shown in a line instead of in an arc |
![]() |
Selector level showing individual outlets or contacts | The individual outlets or contacts may be shown in a line instead of in an arc |
![]() |
Selector level with bridging wiper | |
![]() |
Selector level with non-bridging wiper | |
![]() |
Single-motion selector, non-homing | |
![]() |
Single-motion selector, homing | |
![]() |
Two-motion selector, homing | |
![]() |
Selector, motor driven, homing | |
![]() |
Selector for four-wire switching, homing | |
![]() |
Single-motion selector, set | The selector is set via marked bank contact(s), non homing |
![]() |
Single-motion homing selector with individual outlets | The individual outlets could also be groups of outlets. |
![]() |
Two-motion selector showing levels | |
![]() |
Crossbar selector, general symbol | |
![]() |
Crossbar selector, single connecting unit | |
![]() |
Crossbar selector, four-wire switching | |
![]() |
Antenna, general symbol | |
![]() |
Battery of primary or secondary cells | |
![]() |
Pulse transformer (form 1) |
|
![]() |
Pulse transformer | |
![]() |
Direct current | |
![]() |
Direct current | |
![]() |
Alternating current | |
![]() |
Alternating current (form 2) |
|
![]() |
Piezo-electric effect | |
![]() |
Spring-operated device | |
![]() |
Functional earthing; Functional grounding (US) Functional earthing conductor; Functional earthing terminal |
For the definition of functional earthing, see IEV 195-01-13. |
![]() |
Functional equipotential bonding |
For the definition of functional equipotential bonding, see IEV 195-01-16". |
![]() |
Functional equipotential bonding Functional bonding conductor; Functional bonding terminal |
For the definition of functional equipotential bonding, see IEV 195-01-16". |
![]() |
Capacitor, lead-through Capacitor, feed-through |
|
![]() |
Multiple-function switching device Control and protective switching device (CPS); Reversing CPS |
|
![]() |
Directed connection | |
![]() |
Point of access to a bundle | |
![]() |
Polarized relay, stable positions | Shown with 2 stable positions |
![]() |
Acoustic signalling device, general symbol Horn; Bell; Single-stroke bell; Whistle |
|
![]() |
Combined electric and heat generated station, planned |
|
![]() |
Combined electric and heat generating station, in service or unspecified |
|
![]() |
Fan | The symbol is shown with wiring. The symbol applies symbol 2302 of ISO 14617. |
![]() |
Pump | The symbol is shown with wiring. The symbol applies symbol 2301 of ISO 14617. |
![]() |
Phase-shifting transformer, three-phase (form 1) |
|
![]() |
Phase-shifting transformer, three-phase (form 2) |
|
![]() |
Bushing type voltage transformer (form 1) |
|
![]() |
Bushing type voltage transformer (form 2) |
|
![]() |
Bushing type current transformer (form 1) |
|
![]() |
Bushing type current transformer (form 2) |
|
![]() |
Simplicity voltage detector | |
![]() |
Combined disconnector and earthing switch | Individual actuator equipment may be added. |
Funded by the European Union. Views and opinions expressed are however those of the author(s) only and do not necessarily reflect those of the European Union or the European Education and Culture Executive Agency (EACEA). Neither the European Union nor EACEA can be held responsible for them.
The materials published on the SPARKLE project website are classified as Open Educational Resources\' (OER) and can be freely (without permission of their creators)=>downloaded, used, reused, copied, adapted, and shared by users, with information about the source of their origin.